<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-28 10-22-36
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 56 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 2.9 kHz 86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19002 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 2,12 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Konsertto Sellolle Ja Jousille Nro 2 D-Duuri (Boccherini) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/10/28 10.21.32 Total samples: 19002 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,6 dBr MIN: 0,9 dBr AVE: 2,12 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2025/10/28 10.21.32) 10.08 10.10 10.12 10.14 10.16 10.18 10.20 -1 0 1 2 3 4 Pm [dBr]